feat: add logit-normal timestep sampling to reduce white noise artifacts
Uniform timestep sampling undertrained t>0.8 (the final denoising steps), leaving residual noise that CFG amplifies at inference. Logit-normal sampling concentrates training near t=0.5 while still covering the full range, improving high-t coverage and reducing noise floor in generated audio. Default changed from uniform to logit_normal (sigma=1.0). Previous behavior available with timestep_mode=uniform. Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
This commit is contained in:
@@ -127,6 +127,8 @@ The script will:
|
||||
| `--resume` | `None` | Path to a step checkpoint to resume from (e.g. `lora_output/adapter_step04000.pt`) |
|
||||
| `--precision` | `bf16` | Mixed precision: `bf16`, `fp16`, `fp32` |
|
||||
| `--seed` | `42` | Random seed |
|
||||
| `--timestep_mode` | `logit_normal` | Timestep sampling: `logit_normal` (recommended) or `uniform` |
|
||||
| `--logit_normal_sigma` | `1.0` | Spread of the logit-normal distribution. Only used with `logit_normal` |
|
||||
|
||||
---
|
||||
|
||||
@@ -241,6 +243,22 @@ Add `linear1` to also adapt post-attention projections for large-scale domain sh
|
||||
|
||||
Only add `linear1` once you have 150+ clips — it doubles the adapted parameter count and overfits faster on small datasets.
|
||||
|
||||
### Timestep sampling mode
|
||||
|
||||
The default `logit_normal` mode samples training timesteps from a bell-shaped distribution centered at t=0.5 (via `sigmoid(N(0, σ))`). This gives more training budget to the middle of the noise schedule — the semantically rich region where the model learns what the sound should sound like — while still covering the full range.
|
||||
|
||||
The alternative `uniform` mode samples all timesteps equally. This is mathematically valid but undertrains the high-t region (t > 0.8), which is where final audio quality is determined. Undertraining there leaves residual noise that is then amplified by CFG at inference.
|
||||
|
||||
| Mode | When to use |
|
||||
|---|---|
|
||||
| `logit_normal` (default, σ=1.0) | Recommended for all cases — reduces white noise artifacts |
|
||||
| `uniform` | Baseline / comparison; equivalent to original MMAudio training |
|
||||
|
||||
The `logit_normal_sigma` parameter controls the width of the distribution:
|
||||
- σ=1.0: moderate peak at t=0.5, balanced coverage (default)
|
||||
- σ=0.5: sharper peak, less coverage of extremes
|
||||
- σ=2.0: broader, approaches uniform
|
||||
|
||||
### Adapter strength at inference
|
||||
|
||||